Customization: | Available |
---|---|
Warranty: | 5 |
Phase: | Single |
Still deciding? Get samples of US$ 2000/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Models
|
25K
|
30K
|
33K
|
36K
|
40K
|
Input DC
|
|||||
Recommended max. PV power
|
37.5 kW
|
45 kW
|
49.5 kW
|
54 kW
|
60 kW
|
Max. input voltage
|
1100 V
|
||||
Rated voltage
|
600 V
|
||||
Start-up voltage
|
180 V
|
||||
MPPT voltage range
|
200-1000 V
|
||||
Max. input current
|
32 A / 32 A / 32 A
|
4*32 A
|
|||
Max. short circuit current
|
40 A / 40 A / 40 A
|
4*40 A
|
|||
MPPT number/Max. input strings number
|
3/6
|
4/8
|
|||
Output AC
|
|||||
Rated output power
|
25 kW
|
30 kW
|
33 kW
|
36 kW
|
40 kW
|
Max. apparent output power
|
27.5 kVA
|
33 kVA
|
36.3 kVA
|
39.6 kVA
|
44 kVA
|
Max. output power
|
27.5 kW
|
33 kW
|
36.3 kW
|
39.6 kW
|
44 kW
|
Rated grid voltage
|
3/N/PE, 220 V / 380 V, 230 V / 400 V
|
||||
Rated grid frequency
|
50 Hz / 60 Hz
|
||||
Rated grid output current
|
38.0 A / 36.1 A
|
45.6 A / 43.3 A
|
50.1 A / 47.6 A
|
54.7 A / 52.0 A
|
60.8 A / 57.7 A
|
Max. output current
|
41.8 A
|
50.2 A
|
55.1 A
|
60.2 A
|
66.9 A
|
Power factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
||||
THDi
|
<3%
|
||||
Efficiency
|
|||||
Max. efficiency
|
98.5%
|
98.6%
|
98.7%
|
||
EU efficiency
|
98.1%
|
98.2%
|
98.3%
|
||
Protection
|
DC reverse-polarity protection
|
Yes
|
||||
Short circuit protection
|
Yes
|
||||
Output over current protection
|
Yes
|
||||
Surge protection
|
DC Type II / AC Type II
|
||||
Grid monitoring
|
Yes
|
||||
Anti-islanding protection
|
Yes
|
||||
Temperature protection
|
Yes
|
||||
Strings monitoring
|
Yes
|
||||
I/V Curve scanning
|
Yes
|
||||
Integrated PID recovery
|
Optional
|
||||
Integrated AFCI (DC arc-fault circuit protection)
|
Yes (1)
|
||||
Integrated DC switch
|
Optional
|
General Data
|
|||||
Dimensions (W*H*D)
|
647*629*252 mm
|
||||
Weight
|
37 kg
|
||||
Topology
|
Transformerless
|
||||
Self-consumption (night)
|
<1 W
|
||||
Operating ambient temperature range
|
-25 ~ +60°C
|
||||
Relative humidity
|
0-100%
|
||||
Ingress protection
|
IP66
|
||||
Cooling concept
|
Intelligent redundant fan-cooling
|
||||
Max. operation altitude
|
4000 m
|
Grid connection standard
|
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530
|
||||
Safety/EMC standard
|
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
|
||||
Features
|
|||||
DC connection
|
MC4 connector
|
||||
AC connection
|
OT terminal
|
||||
Display
|
LCD
|
||||
Communication
|
RS485, Optional: Wi-Fi, GPRS
|
Models
|
50K
|
60K
|
60K-HV
|
70K-HV
|
Input DC
|
||||
Max. input voltage
|
1100 V
|
|||
Rated voltage
|
600 V
|
720 V
|
||
Start-up voltage
|
195 V
|
|||
MPPT voltage range
|
180-1000 V
|
|||
Max. input current
|
5*32 A
|
6*32 A
|
||
Max. short circuit current
|
5*40 A
|
6*40 A
|
||
MPPT number/Max. input strings number
|
5/10
|
6/12
|
||
Output AC
|
||||
Rated output power
|
50 kW
|
60 kW
|
60 kW
|
70 kW
|
Max. apparent output power
|
55 kVA
|
66 kVA
|
66 kVA
|
77 kVA
|
Max. output power
|
55 kW
|
66 kW
|
66 kW
|
77 kW
|
Rated grid voltage
|
3/N/PE, 220 V / 380 V, 230 V / 400 V
|
3/PE, 480 V
|
||
Rated grid frequency
|
50 Hz / 60 Hz
|
|||
Rated grid output current
|
76.0 A / 72.2 A
|
91.2 A / 86.6 A
|
72.2 A
|
84.2 A
|
Max. output current
|
83.6 A
|
100.3 A
|
79.4 A
|
92.6 A
|
Power factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
|||
THDi
|
<3%
|
|||
Efficiency
|
||||
Max. efficiency
|
98.7%
|
|||
EU efficiency
|
98.3%
|
98.4%
|
||
Protection
|
DC reverse-polarity protection
|
Yes
|
|||
Short circuit protection
|
Yes
|
|||
Output over current protection
|
Yes
|
|||
Surge protection
|
DC Type II / AC Type II
|
|||
Grid monitoring
|
Yes
|
|||
Anti-islanding protection
|
Yes
|
|||
Temperature protection
|
Yes
|
|||
Strings monitoring
|
Yes
|
|||
I/V Curve scanning
|
Yes
|
|||
Integrated AFCI (DC arc-fault circuit protection)
|
Yes (1)
|
|||
Integrated PID recovery
|
Optional (2)
|
|||
Integrated DC switch
|
Optional
|
|||
General Data
|
||||
Dimensions (W*H*D)
|
691*578*338 mm
|
|||
Weight
|
54.5 kg
|
|||
Topology
|
Transformerless
|
|||
Self-consumption (night)
|
<1 W
|
|||
Operating ambient temperature range
|
-25 ~ +60°C
|
|||
Relative humidity
|
0-100%
|
|||
Ingress protection
|
IP66
|
|||
Cooling concept
|
Intelligent redundant fan-cooling
|
|||
Max. operation altitude
|
4000 m
|
|||
Grid connection standard
|
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530
|
|||
Safety/EMC standard
|
IEC 62109-1/-2, IEC62116 & IEC 61000-6-1/-2/-3/-4
|
|||
Features
|
||||
DC connection
|
MC4 connector
|
|||
AC connection
|
OT terminal (max. 70 mm²)
|
|||
Display
|
LCD, Capacitive touch buttons
|
|||
Communication
|
RS485, USB, Optional: Wi-Fi, GPRS
|
|||
Communication
|
RS485, Optional: Wi-Fi, GPRS, PLC
|
Pls contact for more brand and model.