Nature of Source Flow: | Active Inverter |
---|---|
Certification: | CCC, ISO9001, RoHS, CE, SAA |
Output Power: | 5kw |
Grid Type: | Grid Inverter |
Output Type: | Triple |
Type: | DC/AC Inverters |
Customization: |
---|
Suppliers with verified business licenses
HF Series is new hybrid solar charge inverter, which integrates PV charge &Grid(Generator) charge with AC sine wave output.
Adopting DPS control algorithm, getting higher response speed, higher reliability and higher industrial standard.
Models
|
HF4830U60-H
|
HF4850U80-H
|
AC mode
|
||
Rated input voltage
|
110Vac/120Vac
|
|
Input voltage range
|
(90Vac-140Vac) ±2%
|
|
Frequency
|
50Hz/ 60Hz (auto-sensing)
|
|
Frequency Range
|
47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);
|
|
Overload/short circuit protection
|
Breaker
|
|
Efficiency
|
>95%
|
|
Conversion time (bypass and inverter)
|
10ms (typical)
|
|
AC reverse protection
|
yes
|
|
Maximum bypass overload current
|
63A
|
63A
|
Inverter mode
|
||
Output voltage waveform
|
Pure sine wave
|
|
Rated output power (VA)
|
3500(2900/3000/3200)
|
5000(4100/4300/4500)
|
Rated output power (W)
|
3500(2900/3000/3200)
|
5000(4100/4300/4500)
|
Power factor
|
1
|
|
Rated output voltage (Vac)
|
120Vac(100/105/110Vac settable)
|
|
Output voltage error
|
±5%
|
|
Output frequency range (Hz)
|
50Hz ± 0.3Hz/60Hz ± 0.3Hz
|
|
Efficiency
|
>90%
|
|
Overload protection
|
(102%
(110%125% ±10%: reporting error and turn off the output after 5 seconds; |
|
Peak power
|
7000VA
|
10000VA
|
Loaded motor capability
|
2HP
|
4HP
|
Output short circuit protection
|
Breaker
|
|
Bypass breaker specifications
|
40A
|
63A
|
Rated battery input voltage
|
48V (minimum start voltage 44V)
|
|
Battery voltage range
|
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage alarm/overvoltage restoration…settable LCD screen)
|
|
Power saving mode
AC charging |
Load ≤50W
|
|
Battery type
|
Lead acid or lithium battery
|
|
Maximum charge current
|
40A
|
40A
|
Charge current error
|
± 5Adc
|
|
Charge voltage range
|
40~60Vdc
|
|
Short circuit protection
|
Breaker and blown fuse
|
|
Circuit breaker specifications
|
63A
|
|
Overcharge protection
|
Turn off charge after 1min alarm
|
|
PV charging
|
||
Maximum PV open circuit voltage
|
450V
|
500V
|
PV operating voltage range
|
120-450Vdc
|
120-500Vdc
|
MPPT voltage range
|
120- 430Vdc
|
120- 450Vdc
|
Battery voltage range
|
40-60Vdc
|
|
Maximum output power
|
4200W
|
5000W
|
PV charging current range (can be set)
|
0-60A
|
0-80A
|
Charging short circuit protection
|
Blown fuse
|
|
Wiring protection
Certified specifications |
Reverse polarity protection
|
|
Specification authentication
|
CE(IEC/EN62109-1,-2),ROHS2.0
|
|
EMC authentication grade
|
EN61000
|
|
Operating temperature range
|
-15°C to 55°C
|
|
Storage temperature range
|
-25°C ~ 60°C
|
|
Humidity range
|
5% to 95% (Conformal coating protection)
|
|
Noise
|
≤60dB
|
|
Heat dissipation
|
Forced air cooling, variable speed of fan
|
|
Communication interface
|
USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control
|
|
Size (L*W*D)
|
426mm*322mm*126mm
|
|
Weight (kg)
|
11
|
1. Q: Are you a factory or a trading company?
A :We are a professional Solar Panels Manufacturer in China
2.How can we guarantee the products quality?
A :Always provide the esteemed buyer a pre-production sample before mass production;Always testing every product before despatching the shipments;
3.What products we can supply you?
A :Solar panels,inverter,controller,cable,support frame and other solar power systems
4. Q: Where is your Manufacturer located? How can I visit there?
A :Our factory located in No.6,LinquanEastRoad,FeidongNewCityEconomic DevelopmentZone,231600,Anhui Province PRC
5. Q: Can the products pricing be cheaper?
A :Of course, you will be offered a a very good discount with large quantities.
6. Q: Can print our company's logo on the pv panels?
A :Yes! And we accept the OEM&ODM orders.
Suppliers with verified business licenses